Popis
pThe externally supplied ACT20M-CI-CO, MAS RPS/RPSH, MCZ CFC and WAS/WAZ 4/5 C signal converters/supply isolators can transmit, isolate and convert standardisedbr /DC current signals. They are optionally available in widths of 6 mm (ACT20M/MCZ), 12.5 mm (WAS/WAZ4) or 17.5 mm (WAS/WAZ5).br /br /br /The input and output circuits are completely electrically isolated, as is the power supply.br /The input signal is converted into a DC current/voltage value (ACT20M, WAS/WAZ) or into a proportional frequency (MCZ CFC) between 0–1/4/8/16 kHz. br /The WAVESERIES signal converters are available with a limiting frequency of either 10 Hz (WAS/WAZ4) or 20 kHz (WAS/WAZ5) so that they can process signals quickly.br /br /The MAS/RPS/RPSH supply isolator can supply 2-wire sensors externally. They can also be used optionally to transmit the HART protocol (MAS RPSH).br /br /The 24 VDC supply voltage can be cross-connected on the module side via the CH20M BUS profile (ACT20M series) or using the ZQV4N (MAS/MCZ) or ZQV 2.5N (WAS/WAZ) pluggable jumpers.br /br /International approvals (such as ATEX Zone 2, UL C1D2 and FM Div2) permit use in explosion-risk zones.br //p
| Technické parametry |
| Zátěž | 600 Ω |
| Množství | 10 ks |
| Rozměry | (d x š) 91 mm x 6 mm |
| Rozměr, hloubka | 63.2 mm |
| Vnější délka | 91 mm |
| Vnější šířka | 6 mm |
| Průmyslové zboží | Ano |
| Připojení (součástky) | pružinová svorka |
| Typ (výrobce) | MCZ CFC 4-20MA |
| Max. flexibilní průměr | 1.5 mm² |
| Minimální průřez flexibilní | 0.5 mm² |
| Vstupní signál max. (proud) | 20 mA |
| Vstupní odpor | 50 Ω |
| Napájecí napětí (num.) | 24 V/DC |
| Odběr proudu | 14 mA |
| Typ | MCZ 4-20MA CFC |
| Provozní napětí (rozsah) | 100 V (max) |
| Provozní napětí (max.) | 100 V |
| Splňuje RoHS | ano |
| Vstupní signál (proud) | 4 mA-20 mA |
| Výstupní signál (proud) | 20 mA |
| Hmotnost | 28.3 g |
| Kategorie produktu | měnič signálu |